地质出版社有限公司 中国地质科学院勘探技术研究所主办

锦屏一级水电站左岸抗力体基础处理洞室群围岩稳定性分析

王胜, 黄润秋, 祝华平. 锦屏一级水电站左岸抗力体基础处理洞室群围岩稳定性分析[J]. 钻探工程, 2009, (9): 72-76. doi: 10.3969/j.issn.1672-7428.2009.09.021
引用本文: 王胜, 黄润秋, 祝华平. 锦屏一级水电站左岸抗力体基础处理洞室群围岩稳定性分析[J]. 钻探工程, 2009, (9): 72-76. doi: 10.3969/j.issn.1672-7428.2009.09.021
Analysis on Stability of Surrounding Rock of Underground Chamber Group on Left Bank Resisting Rock of Jinping-I Hydropower[J]. DRILLING ENGINEERING, 2009, (9): 72-76. doi: 10.3969/j.issn.1672-7428.2009.09.021
Citation: Analysis on Stability of Surrounding Rock of Underground Chamber Group on Left Bank Resisting Rock of Jinping-I Hydropower[J]. DRILLING ENGINEERING, 2009, (9): 72-76. doi: 10.3969/j.issn.1672-7428.2009.09.021

锦屏一级水电站左岸抗力体基础处理洞室群围岩稳定性分析

详细信息
  • 中图分类号: TV731.5 TU457

Analysis on Stability of Surrounding Rock of Underground Chamber Group on Left Bank Resisting Rock of Jinping-I Hydropower

  • 通过对锦屏一级水电站左岸抗力体五层洞室岩体结构特征详细调查,采用水电围岩分类的方法对抗力体洞室进行围岩分类.分类结果表明:抗力体洞室围岩以Ⅲ2类围岩居多,占了50%左右,其次为Ⅳ类,占36%左右,Ⅲ1和Ⅴ类围岩所占比例较少.通过对洞室施工开挖失稳破坏现象的调查研究,分析了洞室失稳破坏的机制及破坏形式,认为围岩主要的破坏形式为弱面控制型的块体滑移塌落.对洞室监测资料的分析结果表明,在目前的支护条件下,总体监测未见异常,整体上基础处理洞室监测状态稳定.但F5、F42-9断层及煌斑岩脉等软弱部位应力及变形缓慢增加,需要加强监测.最后根据分析结果提出了建议.
  • 加载中
  • 加载中
计量
  • 文章访问数:  110
  • PDF下载数:  5
  • 施引文献:  0
出版历程
刊出日期:  2009-09-10

目录