中国地质学会岩矿测试技术专业委员会、国家地质实验测试中心主办

碘化钾-甲基异丁基甲酮萃取-火焰原子吸收分光光度法连续测定地球化学样品中痕量银镉铊

徐崇颖, 付爱瑞, 肖凡, 邢刚. 碘化钾-甲基异丁基甲酮萃取-火焰原子吸收分光光度法连续测定地球化学样品中痕量银镉铊[J]. 岩矿测试, 2007, 26(1): 67-70.
引用本文: 徐崇颖, 付爱瑞, 肖凡, 邢刚. 碘化钾-甲基异丁基甲酮萃取-火焰原子吸收分光光度法连续测定地球化学样品中痕量银镉铊[J]. 岩矿测试, 2007, 26(1): 67-70.
Continuous Determination of Trace Silver, Cadmium and Thallium in Geochemical Samples by Flame Atomic Absorption Spectrophotometry with KI-MIBK Extraction[J]. Rock and Mineral Analysis, 2007, 26(1): 67-70.
Citation: Continuous Determination of Trace Silver, Cadmium and Thallium in Geochemical Samples by Flame Atomic Absorption Spectrophotometry with KI-MIBK Extraction[J]. Rock and Mineral Analysis, 2007, 26(1): 67-70.

碘化钾-甲基异丁基甲酮萃取-火焰原子吸收分光光度法连续测定地球化学样品中痕量银镉铊

  • 基金项目:

    河北省地勘局科技计划项目

Continuous Determination of Trace Silver, Cadmium and Thallium in Geochemical Samples by Flame Atomic Absorption Spectrophotometry with KI-MIBK Extraction

  • 研究了碘化钾-甲基异丁基甲酮(KI—MIBK)萃取-火焰原子吸收分光光度法连续测定地球化学样品中痕量银、镉和铊的主要条件。通过对火焰原子吸收分光光度计气路控制系统及雾化器的改进,较大地改善了萃取-火焰原子吸收分光光度法测定银、镉和铊的稳定性和灵敏度。选择萃取酸度为1.2mol/L HCl、水相和有机相体积配比为3:1~4:1,方法精密度(RSD,n=12)为Ag4.5%~9.6%、Cd1.5%~7.9%、T14.5%~5.4%,检出限(3s)为Ag0.004μg/g、Cd0.007μg/g、T10.011μg/g,符合多目标地球化学调查样品测试及质量监控要求。用国家一级标准物质和密码组合标准物质进行验证,测试结果令人满意。
  • 加载中
  • 加载中
计量
  • 文章访问数:  1567
  • PDF下载数:  3
  • 施引文献:  0
出版历程
收稿日期:  2006-03-19
修回日期:  2006-06-07
刊出日期:  2007-02-28