中国地质学会岩矿测试技术专业委员会、国家地质实验测试中心主办

电感耦合等离子体发射光谱法同时测定铅锌矿中银铜铅锌

王小强, 侯晓磊, 杨惠玲. 电感耦合等离子体发射光谱法同时测定铅锌矿中银铜铅锌[J]. 岩矿测试, 2011, 30(5): 576-579.
引用本文: 王小强, 侯晓磊, 杨惠玲. 电感耦合等离子体发射光谱法同时测定铅锌矿中银铜铅锌[J]. 岩矿测试, 2011, 30(5): 576-579.
WANG Xiao-qiang, HOU Xiao-lei, YANG Hui-ling. Simultaneous Quantification of Silver, Copper, Lead and Zinc in Lead-Zinc Ores by Inductively Coupled Plasma-Atomic Emission Spectrometry[J]. Rock and Mineral Analysis, 2011, 30(5): 576-579.
Citation: WANG Xiao-qiang, HOU Xiao-lei, YANG Hui-ling. Simultaneous Quantification of Silver, Copper, Lead and Zinc in Lead-Zinc Ores by Inductively Coupled Plasma-Atomic Emission Spectrometry[J]. Rock and Mineral Analysis, 2011, 30(5): 576-579.

电感耦合等离子体发射光谱法同时测定铅锌矿中银铜铅锌

Simultaneous Quantification of Silver, Copper, Lead and Zinc in Lead-Zinc Ores by Inductively Coupled Plasma-Atomic Emission Spectrometry

  • 采用盐酸-硝酸-硫酸混合酸分解样品,全谱直读电感耦合等离子体发射光谱法同时测定铅锌矿石中的银、铜、铅和锌。基于改善和提高测定结果准确度和精密度的要求,分析了溶液稀释因子和酸度等实验条件对测定结果的影响。结果表明,当溶液的稀释因子为1000,盐酸的体积分数在5%~10%时,测定结果最佳。采用内标法,通过加入钴内标测量分析谱线的相对强度,抵消了由于实验条件的波动引起的影响。方法检出限银为1.96 μg/g,铜为6.00 μg/g,铅为9.00 μg/g,锌为3.00 μg/g,精密度(RSD, n=10)为1.41%~7.50%。方法经国家标准物质分析验证,测定值与标准值相符,结果准确可靠。
  • 加载中
  • 加载中
计量
  • 文章访问数:  1822
  • PDF下载数:  1
  • 施引文献:  0
出版历程
收稿日期:  2010-11-14
修回日期:  2011-01-25
刊出日期:  2011-10-28

目录