中国地质学会岩矿测试技术专业委员会、国家地质实验测试中心主办

超声提取-离子色谱法测定铁矿石中水溶性氟氯溴及硝酸根

胡德新, 马德起, 安鹏升, 王振坤, 王虹, 李权斌, 谷松海, 魏红兵. 超声提取-离子色谱法测定铁矿石中水溶性氟氯溴及硝酸根[J]. 岩矿测试, 2012, 31(2): 287-290.
引用本文: 胡德新, 马德起, 安鹏升, 王振坤, 王虹, 李权斌, 谷松海, 魏红兵. 超声提取-离子色谱法测定铁矿石中水溶性氟氯溴及硝酸根[J]. 岩矿测试, 2012, 31(2): 287-290.
HU De-xin, MA De-qi, AN Peng-sheng, WANG Zhen-kun, WANG Hong, LI Quan-bin, GU Song-hai, WEI Hong-bing. Determination of Water Soluble Fluoride, Chloride, Bromide and Nitrate in Iron Ores by Supersonic Extraction-Ion Chromatography[J]. Rock and Mineral Analysis, 2012, 31(2): 287-290.
Citation: HU De-xin, MA De-qi, AN Peng-sheng, WANG Zhen-kun, WANG Hong, LI Quan-bin, GU Song-hai, WEI Hong-bing. Determination of Water Soluble Fluoride, Chloride, Bromide and Nitrate in Iron Ores by Supersonic Extraction-Ion Chromatography[J]. Rock and Mineral Analysis, 2012, 31(2): 287-290.

超声提取-离子色谱法测定铁矿石中水溶性氟氯溴及硝酸根

  • 基金项目:

    质检公益性行业科研专项(201110235)

Determination of Water Soluble Fluoride, Chloride, Bromide and Nitrate in Iron Ores by Supersonic Extraction-Ion Chromatography

  • 铁矿石样品经超声提取、离心机分离沉淀后,分别通过IC-RP柱、IC-Na柱及0.22 μm微孔过滤膜过滤,25.00 mmol/L NaOH溶液作为淋洗液,利用AS-19型阴离子分离柱和ASRS 300-4 mm连续自动再生化学抑制器分离样品中氟、氯、溴和硝酸根多种水溶性阴离子和采集数据。经过IC-RP柱可吸附样品溶液中有机质,通过IC-Na柱可将溶液中重金属离子置换成Na+,使之与淋洗液的阳离子成分一致。对水溶性阴离子的提取效率进行实验,确定提取时间为30 min。在标准溶液及待测样品溶液中加入一定量相应的淋洗液,使溶液和淋洗液的电导值相匹配来消除水负峰的影响。F-、Cl-、Br-、NO3-的方法检出限分别为2.1、3.5、2.5、2.0 μg/g,工作曲线的相关系数>0.999。用铁矿石标准样品GBW 07218a验证方法的准确度与精密度,测定值与标准值基本吻合,精密度(RSD,n=10)小于5%,加标回收率为96%~104%。用于实际样品的分析,测定值与离子选择电极法结果接近。方法线性范围宽,操作简单,快速高效,适用于实验室日常检测工作。
  • 加载中
  • 加载中
计量
  • 文章访问数:  1385
  • PDF下载数:  5
  • 施引文献:  0
出版历程
收稿日期:  2011-06-23
刊出日期:  2012-04-28

目录