中国地质学会岩矿测试技术专业委员会、国家地质实验测试中心主办

质谱法测定大气颗粒物中多环芳烃的内标选择和质量控制

刘金巍, 安彩秀, 王磊, 王芸, 祁春景, 刘庆学. 质谱法测定大气颗粒物中多环芳烃的内标选择和质量控制[J]. 岩矿测试, 2012, 31(2): 325-330.
引用本文: 刘金巍, 安彩秀, 王磊, 王芸, 祁春景, 刘庆学. 质谱法测定大气颗粒物中多环芳烃的内标选择和质量控制[J]. 岩矿测试, 2012, 31(2): 325-330.
LIU Jin-wei, AN Cai-xiu, WANG Lei, WANG Yun, QI Chun-jing, LIU Qing-xue. The Choice of Internal Standard and Quality Control for the Measurement of Polycyclic Aromatic Hydrocarbons in Airborne Particulates by Mass Spectrometry[J]. Rock and Mineral Analysis, 2012, 31(2): 325-330.
Citation: LIU Jin-wei, AN Cai-xiu, WANG Lei, WANG Yun, QI Chun-jing, LIU Qing-xue. The Choice of Internal Standard and Quality Control for the Measurement of Polycyclic Aromatic Hydrocarbons in Airborne Particulates by Mass Spectrometry[J]. Rock and Mineral Analysis, 2012, 31(2): 325-330.

质谱法测定大气颗粒物中多环芳烃的内标选择和质量控制

  • 基金项目:

    河北省地矿中心实验室资助项目(201103001)

The Choice of Internal Standard and Quality Control for the Measurement of Polycyclic Aromatic Hydrocarbons in Airborne Particulates by Mass Spectrometry

  • 以美国EPA TO-13A标准为基础,研究了气相色谱-质谱法测定大气颗粒物中18种多环芳烃(PAHs)的分析方法,对内标的选择、数据稳定性进行了探讨,对替代物回收率进行统计分析。从内标物和目标化合物的响应衰减相关性、响应因子等确定了各化合物的内标物,BghiP、DBahA、IP、COR的内标物由EPA方法TO-13A中的d10-AC改为d10-PYL,并考查了7天内测试数据的稳定性和365件分析样中替代物回收率。该分析方法的仪器检出限为8~12 pg,目标化合物日常校准测定平均误差为-11.21%~12.12%,相对标准偏差(RSD,n=7)为4.12%~14.27%。替代物的回收率为64.35%~127.94%,平均回收率为76.95%~79.71%,相对标准偏差(RSD,n=365)为7.15%~9.66%。方法数据的稳定性有较大的提高,替代物的回收率等参数符合美国EPA要求,可用于批量或连续分析大气颗粒物中的18种PAHs。
  • 加载中
  • 加载中
计量
  • 文章访问数:  1572
  • PDF下载数:  1
  • 施引文献:  0
出版历程
收稿日期:  2011-10-28
刊出日期:  2012-04-28

目录