中国地质学会岩矿测试技术专业委员会、国家地质实验测试中心主办

电感耦合等离子体发射光谱法同时测定钒钛磁铁矿中钒钛钴镍

王立平, 杨明灵, 张丽, 吴迪, 赵海珍, 尹剑飞. 电感耦合等离子体发射光谱法同时测定钒钛磁铁矿中钒钛钴镍[J]. 岩矿测试, 2012, 31(3): 450-455.
引用本文: 王立平, 杨明灵, 张丽, 吴迪, 赵海珍, 尹剑飞. 电感耦合等离子体发射光谱法同时测定钒钛磁铁矿中钒钛钴镍[J]. 岩矿测试, 2012, 31(3): 450-455.
WANG Li-ping, YANG Ming-ling, ZHANG Li, WU Di, ZHAO Hai-zhen, YIN Jian-fei. Determination of V, Ti, Co and Ni in Vanadium and Titano Magnetite by Inductively Coupled Plasma-Atomic Emission Spectrometry[J]. Rock and Mineral Analysis, 2012, 31(3): 450-455.
Citation: WANG Li-ping, YANG Ming-ling, ZHANG Li, WU Di, ZHAO Hai-zhen, YIN Jian-fei. Determination of V, Ti, Co and Ni in Vanadium and Titano Magnetite by Inductively Coupled Plasma-Atomic Emission Spectrometry[J]. Rock and Mineral Analysis, 2012, 31(3): 450-455.

电感耦合等离子体发射光谱法同时测定钒钛磁铁矿中钒钛钴镍

Determination of V, Ti, Co and Ni in Vanadium and Titano Magnetite by Inductively Coupled Plasma-Atomic Emission Spectrometry

  • 钒钛磁铁矿样品经过氧化钠熔融,盐酸提取,溶液分取稀释后用电感耦合等离子体发射光谱法同时测定其中的V2O5、TiO2、Co、Ni。实验确定过氧化钠的用量为1.5 g,盐酸的用量为10 mL,选择干扰元素较少和背景干扰较小的V、Ti、Co、Ni分析谱线分别为292.4 nm、334.9 nm、230.7 nm、231.6 nm,在稀释因子为10(总稀释因子5000)的条件下进行分析,方法检出限为0.05~0.17 μg/g。用国家一级钒钛磁铁矿标准物质GBW 07225(原矿)、钒钛磁铁矿标准物质GBW 07226a(精矿)、钒钛磁铁矿标准物质GBW 07227(尾矿)验证方法精密度和准确度,方法精密度(RSD,n=12)为0.41%~1.91%;除含量较低的Ni和Co外,相对误差(RE,n=4)均小于5%。通过安装氩气加湿器有效地解决了盐分较大带来的影响,在标准系列中加入等量空白溶液,保持基体与试样一致,消除了基体效应。方法分解样品彻底完全,分析流程简单,易于掌握,一次熔样可以同时测定多种元素,可适用于大批量样品分析。
  • 加载中
  • 加载中
计量
  • 文章访问数:  1575
  • PDF下载数:  1
  • 施引文献:  0
出版历程
收稿日期:  2011-06-23
修回日期:  2012-02-22
刊出日期:  2012-06-28