中国地质学会岩矿测试技术专业委员会、国家地质实验测试中心主办

硝酸-氢氟酸酸溶电感耦合等离子体质谱法测定黑钨矿单矿物中稀土元素

熊采华, 储溱, 赵志飞, 熊玉祥, 柳建一. 硝酸-氢氟酸酸溶电感耦合等离子体质谱法测定黑钨矿单矿物中稀土元素[J]. 岩矿测试, 2012, 31(4): 602-606.
引用本文: 熊采华, 储溱, 赵志飞, 熊玉祥, 柳建一. 硝酸-氢氟酸酸溶电感耦合等离子体质谱法测定黑钨矿单矿物中稀土元素[J]. 岩矿测试, 2012, 31(4): 602-606.
XIONG Cai-hua, CHU Qin, ZHAO Zhi-fei, XIONG Yu-xiang, LIU Jian-yi. Determination of Rare Earth Elements in Wolframite by Inductively Coupled Plasma-Mass Spectrometry with Nitric Acid-Hydrofluoric Acid Discomposition[J]. Rock and Mineral Analysis, 2012, 31(4): 602-606.
Citation: XIONG Cai-hua, CHU Qin, ZHAO Zhi-fei, XIONG Yu-xiang, LIU Jian-yi. Determination of Rare Earth Elements in Wolframite by Inductively Coupled Plasma-Mass Spectrometry with Nitric Acid-Hydrofluoric Acid Discomposition[J]. Rock and Mineral Analysis, 2012, 31(4): 602-606.

硝酸-氢氟酸酸溶电感耦合等离子体质谱法测定黑钨矿单矿物中稀土元素

  • 基金项目:

    国土资源部公益性行业专项(200911043-01)

Determination of Rare Earth Elements in Wolframite by Inductively Coupled Plasma-Mass Spectrometry with Nitric Acid-Hydrofluoric Acid Discomposition

  • 黑钨矿单矿物通常混入铬、钙、镁、钴、钪和稀土等元素,属于富含稀土型矿物,准确测定黑钨矿中的稀土元素对判定黑钨矿矿床的成因相当重要。黑钨矿单矿物样品经硝酸-氢氟酸高压密闭溶解,蒸干除去氢氟酸,以硝酸提取使稀土元素进入溶液,钨则以钨酸的形式从溶液中沉淀而分离,采用电感耦合等离子体质谱法测定稀土元素的含量。用Rh、Re双内标校正,有效地降低了分析信号漂移对分析结果的影响;Ba对153Eu干扰、Pr、Ce对157Gd干扰,采用分析软件在线扣除。该方法消除了钨基体元素的干扰,复溶沉淀实验表明残留稀土相对量小于10%,稀土元素的测定值与过氧化钠碱熔法的结果相符。方法加标回收率为94.2%~104.0%,相对标准偏差小于10%,检出限小于0.026 μg/g。方法简便,准确度高,检出限低,适用于黑钨矿单矿物的分析。
  • 加载中
  • 加载中
计量
  • 文章访问数:  1520
  • PDF下载数:  4
  • 施引文献:  0
出版历程
收稿日期:  2011-12-16
刊出日期:  2012-08-28

目录